Luminol sodium salt
(Synonyms: 鲁米诺钠盐) 目录号 : GC30274A chemiluminescent probe
Cas No.:20666-12-0
Sample solution is provided at 25 µL, 10mM.
Quality Control & SDS
- View current batch:
- Purity: >98.00%
- COA (Certificate Of Analysis)
- SDS (Safety Data Sheet)
- Datasheet
Luminol is a cyclic diacyl hydrazide that exhibits chemiluminescence upon oxidation. For example, HRP, combined with hydrogen peroxide as an activator, causes luminescent peroxidation of luminol.1 This reaction can be enhanced by certain phenol derivatives, such as p-substituted phenols.2 Luminol can also be oxidized, and chemiluminesce, by compounds containing iron, copper, gold, and cyanide.3,4 The excitation/emission maxima for luminol are 355/411 nm.
1.Cormier, M.J., and Prichard, P.M.An investigation of the mechanism of the luminescent peroxidation of luminol by stopped flow techniquesJ. Biol. Chem.243(18)4706-4714(1968) 2.Thorpe, G.H.G., Kricka, L.J., Moseley, S.B., et al.Phenols as enhancers of the chemiluminescent horseradish peroxidase-luminol-hydrogen peroxide reaction: Application in luminescence-monitored enzyme immunoassaysClin. Chem.31(8)1335-1341(1985) 3.Fan, A., Cao, Z., Li, H., et al.Chemiluminescence platforms in immunoassay and DNA analysesAnal. Sci.25(5)587-597(2009) 4.Vladimirov, Y.A., and Proskurnina, E.V.Free radicals and cell chemiluminescenceBiochemistry (Mosc.)74(13)1545-1566(2009)
Cas No. | 20666-12-0 | SDF | |
别名 | 鲁米诺钠盐 | ||
Canonical SMILES | O=C1NNC(C2=C1C=CC=C2N)=O.[Na+] | ||
分子式 | C8H6N3NaO2 | 分子量 | 199.14 |
溶解度 | H2O : 100 mg/mL (502.16 mM; Need ultrasonic) | 储存条件 | Store at 4°C,protect from light |
General tips | 请根据产品在不同溶剂中的溶解度选择合适的溶剂配制储备液;一旦配成溶液,请分装保存,避免反复冻融造成的产品失效。 储备液的保存方式和期限:-80°C 储存时,请在 6 个月内使用,-20°C 储存时,请在 1 个月内使用。 为了提高溶解度,请将管子加热至37℃,然后在超声波浴中震荡一段时间。 |
||
Shipping Condition | 评估样品解决方案:配备蓝冰进行发货。所有其他可用尺寸:配备RT,或根据请求配备蓝冰。 |
制备储备液 | |||
1 mg | 5 mg | 10 mg | |
1 mM | 5.0216 mL | 25.108 mL | 50.2159 mL |
5 mM | 1.0043 mL | 5.0216 mL | 10.0432 mL |
10 mM | 0.5022 mL | 2.5108 mL | 5.0216 mL |
第一步:请输入基本实验信息(考虑到实验过程中的损耗,建议多配一只动物的药量) | ||||||||||
给药剂量 | mg/kg | 动物平均体重 | g | 每只动物给药体积 | ul | 动物数量 | 只 | |||
第二步:请输入动物体内配方组成(配方适用于不溶于水的药物;不同批次药物配方比例不同,请联系GLPBIO为您提供正确的澄清溶液配方) | ||||||||||
% DMSO % % Tween 80 % saline | ||||||||||
计算重置 |
计算结果:
工作液浓度: mg/ml;
DMSO母液配制方法: mg 药物溶于 μL DMSO溶液(母液浓度 mg/mL,
体内配方配制方法:取 μL DMSO母液,加入 μL PEG300,混匀澄清后加入μL Tween 80,混匀澄清后加入 μL saline,混匀澄清。
1. 首先保证母液是澄清的;
2.
一定要按照顺序依次将溶剂加入,进行下一步操作之前必须保证上一步操作得到的是澄清的溶液,可采用涡旋、超声或水浴加热等物理方法助溶。
3. 以上所有助溶剂都可在 GlpBio 网站选购。
3-Aminophthalhydrazide (Luminol) As a Matrix for Dual-Polarity MALDI MS Imaging
In many aspects of the matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI MSI) technique, the discovery of new MALDI matrixes has been a major task for the improvement of ionization efficiency, signal intensity, and molecular coverage. In this work, five analog compounds, including phthalhydrazide, 3-aminophthalhydrazide (3-APH or luminol) and its sodium salt, 4-aminophthalhydrazide (4-APH), and 3-nitrophthalhydrazide (3-NPH) were evaluated as potential matrixes for MALDI Fourier-transform ion cyclotron resonance (FTICR) MSI of metabolites in mouse brain tissue. The five candidate MALDI matrixes were mainly evaluated according to the solid-state ultraviolet absorption, the ion yields and species, and the dual-polarity detection. Among the five candidate matrixes, 3-APH and its sodium salt enabled the detection of endogenous metabolites better than the three other candidates in dual polarities. The best results were observed with 3-APH. Compared with commonly used MALDI matrixes such as 2,5-dihydroxybenzoic acid, α-cyano-4-hydroxycinnamic acid, and 9-aminoacridine, 3-APH exhibited superior performance in dual polarity MALDI MSI, higher sensitivity, broader molecular coverage, and lower background noise. The use of 3-APH led to on-tissue MALDI FTICR MSI of 159 and 207 mouse brain metabolites in the positive and negative ion modes, respectively. Among these metabolites, nucleotides, fatty acids, glycerolipids, glycerophospholipids, sphingolipids, and saccharolipids are included. 3-APH was further used for MALDI FTICR MSI of metabolic responses to ischemia-induced disturbances in mouse brain subjected to middle cerebral artery occlusion (MCAO), thus revealing the alteration of 105 metabolites in the ipsilateral hemispheres. This further emphasizes the great potential of 3-APH as a matrix for the localization of biomarkers in brain diseases.
Chemiluminescent imaging of transpired ethanol from the palm for evaluation of alcohol metabolism
A 2-dimensional imaging system was constructed and applied in measurements of gaseous ethanol emissions from the human palm. This imaging system measures gaseous ethanol concentrations as intensities of chemiluminescence by luminol reaction induced by alcohol oxidase and luminol-hydrogen peroxide-horseradish peroxidase system. Conversions of ethanol distributions and concentrations to 2-dimensional chemiluminescence were conducted on an enzyme-immobilized mesh substrate in a dark box, which contained a luminol solution. In order to visualize ethanol emissions from human palm skin, we developed highly sensitive and selective imaging system for transpired gaseous ethanol at sub ppm-levels. Thus, a mixture of a high-purity luminol solution of luminol sodium salt HG solution instead of standard luminol solution and an enhancer of eosin Y solution was adapted to refine the chemiluminescent intensity of the imaging system, and improved the detection limit to 3 ppm gaseous ethanol. The highly sensitive imaging allows us to successfully visualize the emissions dynamics of transdermal gaseous ethanol. The intensity of each site on the palm shows the reflection of ethanol concentrations distributions corresponding to the amount of alcohol metabolized upon consumption. This imaging system is significant and useful for the assessment of ethanol measurement of the palmar skin.
Ratiometric ECL sensor based on Apt-AuNS@Lu nanoprobe for analyzing cell swelling-induced ATP release
A novel ratiometric electrochemiluminescence (ECL) system based on gold nanostars (AuNSs) support was constructed for the determination of hypotonicity-induced ATP release from HepG2 cells. AuNS@Lu nanoprobe was used as anodic luminophore and K2S2O8 as cathodic luminophore as well as anodic co-reactant. AuNS with the large specific surface was adopted to adsorb plentiful luminol to form solid-state probe and as affinity support to immobilize ATP aptamer (Apt). The obtained nanocomposite (Apt-AuNS@Lu) generated a strong ECL signal at + 0.4 V (vs. Ag/AgCl) with co-reactant K2S2O8, because of excellent conductivity and catalytic activity of AuNS. Furthermore, graphene oxide was reduced onto indium tin oxide (ITO) electrodes to facilitate the electron transfer. Following, polydopamine (PDA) film was formed via self-polymerization, improving stability and adhesion of the electrode surface. To immobilize ATP capture aptamer (AptC), abounding AuNSs were attached to RGO/PDA surface. When the sensor was incubated in the mixture solution of Apt-AuNS@Lu and target ATP, the ECL signal of Apt-AuNS@Lu increased with the increase of ATP concentration, meanwhile, the signal of K2S2O8 declined. The ratio of the two luminophores was used for the quantitative determination of ATP. The linear range was 5 to 250 nM, and the limit of detection was 1.4 nM at (3σ)/S. The method was successfully applied to analyze ATP release from HepG2 cells stimulated by 0.45% NaCl hypotonic solution. The results showed that the release kinetics profile of ATP had a sigmoidal shape with rapid release within 10 min and then slowed. Compared to the isotonic groups, the intracellular ATP concentration was 3.7 ± 0.3 ?M (n = 3) decreasing by 40.3% and the extracellular was 23.4 ± 1.2 nM (n = 3) increasing by 9.2 times in the hypotonicity for 10 min, which showed ATP release from cells and good agreement with commercial ELISA test. The proposed strategy would be beneficial to broadening application of ECL technology in studying cell biological functions.
Aptamer--nanoparticle-based chemiluminescence for p53 protein
A simple colorimetric biosensing technique based on the interaction of gold nanoparticles (AuNPs) with the aptamer was developed for detection of p53, a tumor suppressor protein, in the current study. Aggregation of AuNPs was induced by desorption of the p53 binding RNA aptamer from the surface of AuNPs as a result of the aptamer target interaction leading to the color change of AuNPs from red to purple. The detection limit of p53 protein by the colorimetric approach was 0.1 ng/ml after successful optimization of the amount of aptamer, AuNPs, salts, and incubation time. Furthermore, the catalytic activity of the aggregated AuNPs was greatly enhanced by chemiluminescence (CL) reaction, where the detection limit was enhanced to 10 pg/ml with a regression coefficient of R2 = 0.9907. Here the sensitivity was increased by 10-fold compared with the AuNP-based colorimetric method. Hence, the sensitivity of detection was increased by employing CL, by using the catalytic activity of aggregated AuNPs, on the luminol-hydrogen peroxide reaction. Thus, the combination of colorimetric and CL-based aptasensor can be of great advantage in increasing the sensitivity of detection for any target analyte.
Existence of a new reactive intermediate oxygen species in hypoxanthine and xanthine oxidase reaction
We investigated a hypoxanthine (HPX) and xanthine oxidase (XOD) reaction by using a luminol analog 8-amino-5-chloro-7-phenylpyrido[3,4-d]pyridazine-1,4-(2H,3H)dione sodium salt (L-012)-mediated chemiluminescence (CL) response. Addition of a high activity of superoxide dismutase (SOD), a potent O2* scavenger, and of a high concentration of 5,5-dimethyl-1-pyrroline-N-oxide (DMPO), a potent spin trapping agent, diminished completely the CL response. Whereas a high concentration of dimethyl sulfoxide (DMSO), as a potent *OH scavenger could not attain to the complete diminishment of the CL response. It has been reported that luminol monoanion reacts with *OH to form luminol radical, and then resultant luminol radical reacts with O2* to elicit CL response. Complete scavenging for *OH is assumed to result in lack of luminol radical, which in turn induces lack of CL response. However, our results did not support the idea. Furthermore, we examined the effect of L-012 on the DMPO-OOH formation in the presence or absence of DMSO in the HPX-XOD system by applying an electron spin resonance (ESR)-spin trapping method. The DMPO-OOH formation was inhibited even in the presence of DMSO, and the rate constant (k2) between L-012 and O2* obtained in the presence of DMSO was 9.77 x 10(2) M(-1) s(-1) and the constant in the absence of DMSO was 2.97 x 10(3) M(-1) s(-1). The data suggests that L-012 is converted to a radical form that reacts with O2* even under the conditions of the absence of *OH. From these, we postulate that the existence of a reactive intermediate oxygen species in the HPX-XOD system.